Keyscan Panel Not Reporting Transactions

GHS Panel was no longer reporting transactions.

I cleared memory by jumping J1 on board.

Spare jumpers could be found on J16 to the left.

They said to allow about 10 minutes for it to be cleared.

Then in Keyscan

Quickbuttons > Selective Update

Select all options at top, select the panel in question and click update.